false
OasisLMS
Login
Catalog
ASGE DDW Videos from Around the World | 2026
ENDOSCOPIC CLOSURE OF DUODENO-CUTANEOUS FISTULAE U ...
ENDOSCOPIC CLOSURE OF DUODENO-CUTANEOUS FISTULAE USING A NOVEL TISSUE-ENGINEERED MATRIX SYSTEM
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
The video presents two cases of chronic duodenocutaneous fistula closed endoscopically using a rolled bovine pericardial tissue matrix plug plus intraluminal endoscopic vacuum therapy. After identifying the fistula tract, the team performed argon plasma coagulation to deepithelialize it, then inserted and anchored the plug to create a mechanical seal and promote healing. In both patients, contrast studies showed no leak within 1–2 weeks, EVT was removed, and oral feeding resumed. The authors conclude this combined technique may be an effective alternative when clips fail in fibrotic, high-output fistulae.
Asset Subtitle
Video Plenary I
Submitted by Amol Bapaye
Keywords
chronic duodenocutaneous fistula
endoscopic closure
bovine pericardial plug
endoscopic vacuum therapy
argon plasma coagulation
×
Please select your language
1
English